1.Bending dimensions (for bending semi-rigid cables)
Available to discuss your needs upon request.
(mm)| Bending Form Cable | R Bending | U Bending | Continuous R Bending | Continuous R Bending | ||
|---|---|---|---|---|---|---|
|
|
|
|
|||
| SMA | SX-36 | < R:8 > < R:10 > | L:20.0 | L:26.0 | L:7.5 | L:7.5 |
| SX-22 | < R:5 > | L:20.0 | L:25.0 | L:5.0 | L:5.0 | |
| SX-12 | < R:5 > | L:26.0 | L:26.0 | L:5.0 | L:5.0 | |
| 1.85mm V 2.92mm K |
SX-22 | < R:10 > | L:30.0 | L:28.0 | L:7.0 | L:7.0 |
| < R:5 > | L:25.0 | L:25.0 | L:6.0 | L:6.0 | ||
| SX-12 | < R:10 > | L:32.0 | L:28.0 | L:7.0 | L:7.0 | |
| < R:5 > | L:27.0 | L:25.0 | L:5.0 | L:5.0 | ||
R-bending is a prime example of a plug application.
Please contact us for details.
2.Assembly length criteria
Between connector tips
L-type is between the center conductors
With fixed flange, the lower part of the flange
3.Dimensional tolerance
■Semi-rigid/semi-flexible total length
(mm)| Dimension classification | common difference |
|---|---|
| L≦100 | ±3 |
100| ±5 |
|
300| ±10 |
|
500| ±15 |
|
1000| ±(L×0.03) |
|
■ Terminal Processing Dimensions
(For semi-rigid, no-bend cases)